A gray outdoor heat pump unit with a circular fan grille sits on a concrete pad beside a dark wood-clad house, next to a gravel bed with ornamental grasses and a stepping-stone path.

A pro who works on heat pumps

Best heat pump setting for an Idaho winter

Idaho winters put a heat pump through real cold, and the thermostat setting you pick affects how hard it works and when backup heat kicks in. This page gets into where to set it and why, plus what a yearly checkup catches before a cold snap finds it. Answer a few questions and a contractor who handles heat pumps in your area will follow up.

Match me with a pro

Set your heat pump to a steady temperature and leave it there through the winter. Pick a number you can live with, say 68, and don't bump it down at night or while you're out. A heat pump moves heat instead of burning fuel to make it, so recovering several degrees after a setback takes it longer and often pulls in the backup heat strip to catch up. That backup heat costs more to run than the heat pump itself. In an Idaho winter, with real cold settling in for stretches, the outdoor unit is already working against a big difference between outside air and your house. Asking it to also climb out of a deep setback just adds to that load. A steady setting lets the heat pump run longer at a lower, steadier output, which is how it's meant to work. If your home has a programmable thermostat built for a furnace, check that it isn't set up for the kind of deep setbacks that make sense with gas heat but not here.

A gray-haired bearded man in a dark coat and scarf dusted with snow stands smiling in a dimly lit entryway with a white front door, a side table with a lit lamp, an oval mirror, and a patterned rug.
An older bearded man in a dark snow-dusted coat and gray scarf stands just inside a dimly lit home entry, with a framed picture, lit table lamp, and an adjoining room with a fireplace behind him, and snow visible through the open door.
A gray-haired, bearded man in a dark snow-dusted coat stands smiling in a dimly lit entry hall with a staircase, a lit table lamp, a framed picture, and a living room visible through a doorway.
An older man with gray hair and a beard, wearing a dark jacket dusted with snow, stands smiling in a dimly lit hallway with lamps and a living room visible behind him.

Why setbacks backfire on a heat pump

A furnace can shove the temperature up fast because it burns gas to make heat on demand. A heat pump doesn't work that way. It moves heat from the cold outside air into your house, and when it's 20 degrees out, that process runs slower. Drop your thermostat 5 or 6 degrees overnight, and the heat pump often can't recover fast enough by morning, so the backup heat strip kicks in to close the gap. That strip is electric resistance heat, the same expensive way space heaters work, and it costs more to run than the heat pump itself. A steady setting keeps the house in range of what the heat pump can handle on its own.

What a checkup catches before the cold

A heat pump that has to run harder than it should will show it somewhere, usually in the coil or the refrigerant charge. A tech checking yours before winter will look at the refrigerant level, since a system running low won't move heat as well and will lean on backup heat more than it needs to. They'll also check the outdoor coil for dirt or buildup, since airflow across it matters as much in January as it does in July, and clear the condensate drain so defrost cycles drain properly instead of icing up. Catching a weak spot in the fall means the system is pulling its full weight once the cold settles in.

A woman wrapped in a thick beige fleece blanket sits on a sofa with an open book on her lap, beside a lit table lamp, with a frost-covered window behind her.
A gray-haired woman in a cream knit sweater stands in a dimly lit kitchen at night, looking to her right, with a round loaf of bread in the foreground and a dark window and potted plant behind her.

Your heat pump doesn't make heat the way a furnace does. Outside, a reversing valve sends refrigerant through the system backward from how it runs in summer, pulling warmth out of the cold air and moving it inside. That works fine down to a point. Once the outdoor temperature drops into the 30s, the compressor starts struggling to pull enough heat to keep the house at your setting, and the strip heat built into the air handler switches on to cover the gap. That's electric resistance heat, and it costs more to run than the compressor alone. Cold, damp weather adds another wrinkle: frost collects on the outdoor coil, so the system runs a defrost cycle every so often, briefly reversing itself, which is why you'll sometimes feel cool air from the vents for a few minutes. Every time the thermostat has to recover lost ground, that's exactly when strip heat is most likely to kick in. A maintenance check looks at refrigerant charge and coil condition, since both set how far the compressor can carry the load before backup heat has to step in.

What's Happening Inside the Unit

  • A heat pump's outdoor unit has a reversing valve that switches the refrigerant flow so the same equipment can heat in winter and cool in summer.
  • Below a certain outdoor temperature, usually somewhere in the 30s, the compressor can't pull enough heat from the air to keep up, and backup heat kicks in.
  • That backup heat is electric resistance heat, strip heat built into the air handler, and it costs more to run than the compressor does.
  • Frost builds up on the outdoor coil in cold, damp weather, so the system runs a defrost cycle that briefly reverses itself and can blow cool air from the vents.
  • A thermostat set lower at night forces the system to recover that lost heat later, which is exactly when backup strip heat is most likely to engage.
  • A maintenance visit checks refrigerant charge and coil condition, both of which determine how low the compressor can work before backup heat has to take over.
An outdoor air conditioner condenser unit on a concrete pad beside a house with horizontal lap siding, with a shrub to the left, bare dirt in front, and conduit and a metal disconnect box on the wall.
Before you get your heat pump maintenance
A gray outdoor condenser unit on a concrete pad beside a white horizontal-siding house, with refrigerant lines and conduit running to a wall-mounted disconnect box, bare soil in front and a green shrub at left.
After you get your heat pump maintenance
A beige outdoor condenser unit on a gray pad beside a house with gray horizontal siding, with refrigerant lines and an electrical disconnect box on the wall, bordered by dark mulch, a stone retaining wall with shrubs, and a paver walkway.

Get your heat pump to the right pro

Send the form, and lining up the heat pump tune-up stops being yours to chase.

A local pro who services heat pumps gets in touch about the tune-up.

Hand it off

There's no charge for the request.

Steady Setting vs. Nighttime Setback

Steady setting

  • The compressor holds a steady load instead of ramping up hard after a drop, which is the easier way to run it on a cold night.
  • Backup heat stays off more often because the system never has to claw back several degrees at once.
  • Rooms stay even through the day and night since the thermostat isn't asking for a swing in either direction.
  • With power cheap in Idaho, a steady setting doesn't carry the same bill penalty it would somewhere power costs more.
  • You set it once in the fall and leave it, so there's nothing to remember to adjust each night.

Nighttime setback

  • Dropping the temperature at night means the heat pump has to recover that lost ground in the morning, often into cold outdoor air.
  • A setback of more than a couple degrees on a heat pump can trigger backup heat just to catch up, which most homes here don't have wired for regular use since they heat with gas.
  • Recovery runs longer than a furnace would need, because the heat pump is pulling heat from outside air instead of burning it on demand.
  • The bedroom might feel colder overnight, but the system pays for it with a harder push before breakfast.
  • Any savings from the lower nighttime setting can get eaten up by the slow, inefficient recovery that follows it.
A gray outdoor air conditioning condenser unit on a concrete pad beside a house with horizontal siding, next to a green lawn and a plain light-colored wall.

What a steady setting looks like at home

You'll notice it most on the coldest mornings. Set at a steady 68, the vents keep moving warm air at a pace you barely register. Walk past the thermostat and the backup heat light stays off. That's the system pulling heat from outside air a little at a time instead of racing to catch up. Rooms near the return stay closer in temperature to rooms far from it, because the system isn't lurching between idle and full output.

A white outdoor heat pump unit on a concrete pad beside a plain light wall, with gravel and mowed grass in front.

What a setback costs you here

Idaho winters push outdoor air into the 20s and teens for stretches, and that's exactly when a setback hurts most. Drop the thermostat 6 or 7 degrees overnight and the heat pump has to claw that back in cold air that holds little heat to give. Backup heat steps in to close the gap, and electric resistance heat costs more to run than the heat pump alone, even with cheap power. You'll see it as a jump on the bill the month you tried saving a few degrees.

Power costs 11.83 cents per kilowatt-hour statewide

At 11.83 cents a kilowatt-hour, running the compressor steady costs less than making it recover several degrees every time backup heat kicks in. Holding one temperature all winter keeps that rate working for you instead of against you on the coldest nights.

EIA-861 2025 statewide residential average

A man seen from behind raises his hand to wave at a woman standing in the open front doorway of a single-story house with gray shingle siding, white columns and a gabled porch entry.

One number, held steady, all winter

Pick your temperature and leave your hands off the thermostat until spring. That's the whole answer. A heat pump rewards patience more than any other system in your house, and Idaho's cold mornings are exactly when that patience gets tested.

A yearly checkup is what keeps that steady setting working the way it should. A tech can catch a refrigerant level that's drifted low or a coil that's dirty, the kind of thing that makes a perfectly good setting feel like it's not keeping up. If you want that looked at before the next cold snap, you can get matched with a contractor who takes on heat pump maintenance in your area, and they'll reach out to go over what your system needs.

A living room corner with a beige upholstered armchair holding navy and striped cushions, a small round wooden side table with a carved bowl and a potted green plant, a framed landscape picture on a pale wall, built-in shelving, and a curtained window.
An outdoor air conditioning or heat pump condenser unit sits on a concrete pad surrounded by gravel beside a dark horizontal-sided house, with grass and shrubs nearby.

The right pro for this job

Send the request and finding a pro stops being your problem.

Step 1 of 3: Equipment